EO6-Operate Alternators and Generators

Search this section

Choose a question set and start learning or take an exam.

About this collection

Videotel questions are grouped by professional topic, including machinery, electrical equipment, fuel and ballast operations. Choose a subject relevant to your preparation.

“Видеотел — Engine Category — EO6-Operate Alternators and Generators” contains 172 questions across 1 collection.

Learning

Learning mode has no timer. After answering, you see feedback and the correct options. You can return to a question and repeat a topic.

Exam

A practice exam lasts up to 60 minutes and includes up to 50 questions from the selected collection. Correct answers and results appear after completion.

Sample questions and answers

These examples come from the published collection. Choose Learning to study questions in sequence, or Exam to check your knowledge.

What information would you find on the name plate of any industrial transformer.The source image is unavailable.

One correct answer

  • 1) Power, current, horsepower, ampereage.
  • 2) Power, voltage, transformation rate, impedance.
  • 3) Polarity marking, kVA, impedance, voltages, maker.
  • 4) kVAR rating, voltage, impedance, BIL rating, polarity.✓ Correct answer
How can you monitor the correct instant for synchronising alternators should your synchronising system (synchronoscope or lamps) be defective ?The source image is unavailable.

One correct answer

  • 1) By fitting a voltmeter over one phase.✓ Correct answer
  • 2) By fitting lamps over the three phases.
  • 3) By fitting lamps crossed over two phases.
  • 4) By fitting two voltmeters crossed over two phases.
Which are the two requirements to make electricity generation possible ?The source image is unavailable.

One correct answer

  • 1) Presence of magnetic flux, relative motion between conductor and flux.✓ Correct answer
  • 2) Current to induce flux, rotary movement.
  • 3) Power to induce magnetic flux, power to rotate.
  • 4) Current to induce flux, conductor motion cutting flux.
What are ideal conditions for taking Megger test readings of an alternator?The source image is unavailable.

One correct answer

  • 1) Hot after stopping.✓ Correct answer
  • 2) Cooled down to hand-warm.
  • 3) Cooled down to ambient temperature.
  • 4) Running.
If a total short circuit occurs on a 3 phase alternator and the short-circuit trip fails to operate, what back-up safety device will activate ?The source image is unavailable.

One correct answer

  • 1) The preferential trip.
  • 2) The low frequency trip.
  • 3) The overspeed trip.
  • 4) The under voltage trip.✓ Correct answer

Before you start

Do I need to register to start?

Guest access lasts 23 minutes. Free registration lets you continue without limits, save progress and review mistakes in your account.

What language are the questions in?

Questions and answer options retain the language of the original bank. You can change the interface language separately.

Can I use my result as an official document?

No. This is independent practice. A result does not replace an examination, certificate or knowledge check by an authorised organisation.