CD0018. Cooling Systems

Search this section

Choose a question set and start learning or take an exam.

About this collection

The Seagull CBT bank is organised into modules covering safety, shipboard operations, maintenance and other topics. Original module names and codes are retained to help you find the topic you need.

“Seagull CBT — CD0018. Cooling Systems” contains 67 questions across 1 collection.

Learning

Learning mode has no timer. After answering, you see feedback and the correct options. You can return to a question and repeat a topic.

Exam

A practice exam lasts up to 60 minutes and includes up to 50 questions from the selected collection. Correct answers and results appear after completion.

Sample questions and answers

These examples come from the published collection. Choose Learning to study questions in sequence, or Exam to check your knowledge.

At which point in a diesel engine jacket cooling water system is the temperature normally measured for temperature control purposes?

One correct answer

  • At the engine outlet.✓ Correct answer
  • At the outlet from the heat exchanger.
  • At the header tank.
  • At the engine inlet.
Where would you find detailed information relating to health and safety and environmental hazards associated with cooling water system treatment chemicals?

One correct answer

  • From the material safety data sheets.✓ Correct answer
  • On the packaging or container for the treatment.
  • In the engine manual.
  • From the delivery note.
Chromate based corrosion inhibitors are not allowed as the cooling water treatment in some situations. In which of the following must alternatives be used?

One correct answer

  • When the system includes a fresh water generator for producing potable water.✓ Correct answer
  • When the system includes a fresh water generator for producing boiler feed water.
  • When the system doesn’t include a fresh water generator.
  • In a central cooling system.
Which of the following values would be a typical value for the specific heat capacity of a mineral oil?

One correct answer

  • 2.0 kJ/kgK✓ Correct answer
  • 2.0 kJ
  • 4.2 kJ/kgK
  • 4.0 kJ
How should the jacket water flow through the deaerator?

One correct answer

  • With a rotational flow through the baffles.✓ Correct answer
  • Vertically upwards through the baffles.
  • Vertically downwards through the baffles.
  • From the center outwards through the baffles.

Before you start

Do I need to register to start?

Guest access lasts 23 minutes. Free registration lets you continue without limits, save progress and review mistakes in your account.

What language are the questions in?

Questions and answer options retain the language of the original bank. You can change the interface language separately.

Can I use my result as an official document?

No. This is independent practice. A result does not replace an examination, certificate or knowledge check by an authorised organisation.